Using modular bathrooms can save cash, labour and time, says Peter Mayer. So here鈥檚 a shower of useful information to consider when specifying and fitting

Bathrooms make an ideal candidate for prefabrication, being relatively small and self-contained units. Furthermore, sanitary and services provision is expensive. Bathrooms typically account for 6-10% of the capital cost of a hotel, so prefabricating them can mean significant savings.

With traditional building, a multitude of trades needs to be organised to realise the bathroom design. This requires a high degree of supervision and management on site to ensure correct sequencing and quality of work from plumbers, electricians, tilers, floor layers, sealant applicators, decorators, glaziers, carpenters and other specialists.

Modular bathrooms or bathroom pods do away with most of these issues and although the capital cost may not be less than site-constructed bathrooms, savings from waste and improved quality result in less snagging and better performance in use. More significantly, reduced construction times mean earlier income streams from the property.

Specification variation

There is no such thing as a standard bathroom pod; what you specify is what you get. However, there will be cost benefits in specifying to manufacturers鈥 鈥渟tandards鈥 or in large volumes. Depending on the complexity and manufacturer a minimum order of 10 to 100 pods may be required for a reasonable final cost. Larger quantities allow further spreading of set鈥搖p costs, for example, making a prototype and tooling up.

The range of options for specification are limitless, but it is worth bearing in mind that the capital costs of the bathroom pods are influenced by the structure, size, shape and quality of finishes and sanitaryware. Typically they include:

  • Structure: this may be precast concrete panels, timber or steel frame, reinforced glass fibre or a composite panel system.
  • Internal linings and finishes: wall finishes are typically ceramic tiles to BS EN 14411 on a moisture resistant or waterproof lining. Tanking may be an option. The floor to wall, bath edge and shower tray wall are the key junctions to resolve to prevent water penetrating the lining and structure.
  • Sanitaryware: basins and WCs are typically vitreous china to BS 3402, baths enamelled steel to BS 1390. Shower enclosures are usually made from safety glass with an aluminium frame.
  • Services: electrical and plumbing should be to the relevant standards complete with a commissioning certificate after installation.
  • Distribution and waste pipework: these are normally plastic waste and supply pipework, or copper supply pipes.
  • Fixtures and fittings: the range is vast and may include mirrors, soapholders and glass shelves.

Functional requirements

Keeping water 鈥 liquid and vapour 鈥 where it doesn鈥檛 harm the fabric is a key functional requirement but it is by no means the only consideration. The relevant sections of the 黑洞社区 Regulations apply with further guidance provided from national secondary documentation: approved documents, technical standards and technical booklets. One potential issue is when the pod is placed on the structural floor of a building, as this may result in a step to gain access, and could compromise accessibility and contravene

Part M of the 黑洞社区 Regulations. One solution is to specify floorless pods.

Managing the off-site process

Early agreement and a freeze of the design is important. The design process works best where the supply chain is integrated and based on an audited quality control system to ISO 9001. Early freeze allows the factory enough time to schedule manufacture; the downside is that variations may be costly.

黑洞社区 tolerances and allowances for site positioning are important to ensure the pods fit with other building elements and services connections. Additional structural provision may need to be made to accommodate the loads associated with the bathroom pods.

The protection, storage, transport, lifting and manoeuvring of the pods should be considered in the context of the time of year, programming and site access. Also, if pods are sourced from abroad, ensure that lifting provision is to the UK standards.

Pods in use

In theory the maintenance burden for a prefabricated bathroom should be no more, if not less, than a similar site-fabricated version. The key is to plan for easy access to the services. It should be possible to detect and remedy any leak before the underlying structure is affected.