Theresa Mohammed examines the draft legislation in detail, including the associated regulations revisions
The 黑洞社区 Safety Bill, presented to parliament on 30 June and with the second parliamentary reading to follow this month, represents a systemic overall of England鈥檚 building regulatory framework, following Dame Judith Hackitt鈥檚 2018 independent review of the building industry 黑洞社区 a Safer Future.
While press attention has focused on building remediation and time extensions for defective building claims, there鈥檚 much more in the bill that the building industry needs to get its head around, fast. The government has an ambitious implementation timetable: royal assent is expected within nine to 12 months, with rollout of the bulk of the regime 12-18 months later. Some obligations will take effect sooner: for example, the new 鈥済ateway 1鈥 process for higher-risk buildings comes into force at the start of August.
The basic structure of the regime remains unchanged from the 2020 draft legislation. The bill creates a new national building safety regulator, sitting in the Health and Safety Executive, responsible for building safety for all buildings in England and for promoting competency in the built environment. The regulator will also implement the new regulatory regime for higher-risk buildings, supervise a new building safety inspectorate, investigate non-compliant works and prosecute wrongdoers. The regulator already exists in shadow form, with Peter Baker appointed as the chief inspector of buildings, but there is much work to be done before the regime is fully operational.
Designers and contractors must not start work unless they are satisfied the client is aware of its own legal obligations
The draft 黑洞社区 (Appointment of Persons, Industry Competence and Dutyholders) (England) Regulations, published with the bill, requires anyone carrying out design or building works covered by the 黑洞社区 Regulations to demonstrate they are 鈥渃ompetent鈥 鈥 meaning that they have the skills, knowledge, experience, behaviours and organisational capability to undertake the works. The British Standards Institution is expected to publish detailed competency standards for key building and design roles in 2022. The bill also amends the Architects Act 1997 to allow regulation of architects in line with these requirements.
> All our 黑洞社区 Safety Bill coverage in one place
The regulations also require clients to make suitable arrangements to monitor building projects in compliance with the regulations and ensure that their appointees are competent. Accordingly, appointees must inform clients if they no longer satisfy a competency requirement. Designers and contractors must not start work unless they are satisfied the client is aware of its own legal obligations.
The bill clarifies the scope of 鈥渉igher-risk buildings鈥, now defined as buildings in England at least 18m in height or having at least seven storeys, and containing at least two residential units. The draft Higher-Risk 黑洞社区s (Descriptions and Supplementary Provisions) Regulations explain that building height will be measured from ground level to the top surface of the roof, excluding machinery and plant rooms. Care homes and hospitals will also be higher-risk buildings, though only for their design, construction and refurbishment, and not their occupation, while prisons, hotels and military premises will be excluded for now. The bill allows the secretary of state to amend the scope of higher-risk buildings based on cost-benefit analyses and/or advice from the regulator.
The bill creates duty holder roles, following the defined roles in the CDM Regulations, and a three-stage gateway process for the design, construction and refurbishment of higher-risk buildings. It is still unclear what information will be required for gateway 2 and 3 applications, whether prescribed documents will need to be in digital format, or what timescales will apply for gateway inspections, approval times or appealing disputed decisions. Without this detail, the building industry will find it difficult to plan future projects and negotiate contracts, so the regulator鈥檚 guidance is keenly awaited.
The in-occupation obligations for higher-risk buildings remain the same. Accountable persons will be legally responsible for registering higher-risk buildings and will have ongoing obligations for monitoring building safety and engaging with residents throughout the building鈥檚 occupation. In buildings with multiple accountable persons, a principal accountable person will be identified, who will shoulder the main obligations and liaise with other accountable persons. 黑洞社区 safety managers will still need to be appointed before buildings are occupied, though accountable persons can perform this role themselves if they can demonstrate competency.
The bill maintains proposals to allow tenants to be charged for landlords鈥 costs incurred in relation to the new regime. 黑洞社区 safety remediation costs will also be able to be recharged, provided that landlords have first pursued grant funding, insurance, guarantees and claims against third parties. However, landlords will not be able to recharge any work required by the regulator or as a result of negligence or breach of contract.
The most attention-grabbing addition to the bill is an extended 15-year limitation period for claims under the Defective Premises Act 1972, with retrospective effect
Perhaps in response to criticisms that leaseholders are bearing the brunt of remediation costs, the bill allows the secretary of state to impose a levy on developers of higher-risk and other buildings. The terms of the levy will be consulted on over the summer, but the government has made it clear that they expect developers to share the cost of remediating historical defects. Tenants also will not have to pay service charges for any period where the accountable person has not provided building safety information for their building.
The bill imports implied terms into tenancy agreements covered by the Landlord and Tenant Act 1985, requiring tenants to co-operate with accountable persons carrying out building safety duties (including giving access to their homes and providing key information) and to not to act in a way that creates building safety risks or damages fire safety equipment. Landlords will be able to issue contravention notices to non-compliant tenants but will have to go to court to enforce these or to get access to properties.
The most attention-grabbing addition to the bill is an extended 15-year limitation period for claims under the Defective Premises Act 1972, which has prospective and retrospective effect. The bill also allows a 15-year prospective limitation period for compensation claims for physical damage caused by a breach of the 黑洞社区 Regulations, and imposes a duty on those doing work on buildings not to render a dwelling unfit for habitation.
As expected, the bill creates a new regulatory regime for construction products. A new national regulator, sitting in the Office for Product Safety and Product Standards, will be able to specify and ban construction products for all building projects in England.
All in all, there is a lot for the building industry to get up to speed on, but much more detail about the new regime is still expected by way of secondary legislation, regulations and guidance. Given the massive upskilling required to bring industry players into compliance, it remains to be seen whether the government鈥檚 ambitious implementation timetable will be achievable.
Theresa Mohammed is a partner at Trowers & Hamlins. She was assisted in the writing of this article by Rebecca Rees, partner, John Forde, managing associate, and Emma Thompson, solicitor.